The Mach-Zehnder interferometer (named after physicists Ludwig Mach (son of Ernst Mach) and Ludwig Zehnder) is a device used to determine the phase shift caused by a small sample which is placed in the path of one of two collimated beams (thus having plane wavefronts) from a coherent light source. In contrast to the Michelson interferometer, there are two output ports.
[edit] How it works[edit] Set-upA collimated beam is split by a half-silvered mirror. The two resulting beams (the "sample beam" and the "reference beam") are each reflected by a mirror. The two beams then pass a second half-silvered mirror and enter two detectors ("detector 1" and "detector 2"). It is important that the fully-silvered and half-silvered surfaces of all mirrors, except the last, face the inbound beam, and that the half-silvered surface of the last mirror faces the outbound beam exiting in the same orientation as the original collimated beam. That is, if the original beam is horizontal, the half-silvered surface of the last mirror should face the horizontally outbound beam. [edit] PropertiesIt is important to consider that the medium of a mirror is what lies behind it; that is, if a glass substrate has its half-silvered or fully-silvered surface facing the inbound beam, then the inbound beam travels through air and is reflected off the surface of a glass medium – if, however, the half-silvered or fully-silvered surface faces away from the inbound beam, then the inbound beam travels through glass and is reflecting off the surface of an air medium. The following rules apply to phase shifts due to material:
Given the above rules, mirrors, including half-silvered mirrors, have the following properties:
[edit] Observing the effect of a sampleWithout a sample, there is no phase difference in the two beams in detector 1, yielding constructive interference. Both beams will have undergone a phase shift of wavelength + k due to two front-side reflections and one transmission through a glass plate. At detector 2, there is a phase difference of 0.5*wavelength, yielding complete destructive interference. The reference beam into detector 2 has undergone a phase shift of 0.5*wavelength + 2k due to one front-side reflection and two transmissions. The sample beam into detector 2 has undergone a wavelength + 2k phase shift due to two front-side reflections and one rear-side reflection. Therefore, when there is no sample, only detector 1 receives light. If a sample is placed in the path of the sample beam, the intensities of the beams entering the two detectors will change, allowing the calculation of the phase shift caused by the sample. [edit] See also
[edit] Flow visualisation techniques[edit] References