Glucose tolerance test:
Diabetes mellitus
Types of Diabetes
Diabetes mellitus type 1
Diabetes mellitus type 2
Gestational diabetes

Pre-diabetes:
Impaired fasting glycaemia
Impaired glucose tolerance

Disease Management
Diabetes management:
Diabetic diet
Anti-diabetic drugs
Conventional insulinotherapy
Intensive insulinotherapy
Other Concerns
Cardiovascular disease

Diabetic comas:
Diabetic hypoglycemia
Diabetic ketoacidosis
Nonketotic hyperosmolar

Diabetic myonecrosis
Diabetic nephropathy
Diabetic neuropathy
Diabetic retinopathy

Diabetes and pregnancy

Blood tests
Blood sugar
Fructosamine
Glucose tolerance test
Glycosylated hemoglobin

A glucose tolerance test in medical practice is the administration of glucose to determine how quickly it is cleared from the blood. The test is usually used to test for diabetes, insulin resistance, and sometimes reactive hypoglycemia. The glucose is most often given orally so the common test is technically an oral glucose tolerance test (OGTT). The test may be performed as part of a panel of tests, such as the comprehensive metabolic panel.

Contents

[edit] Preparation and cautions

The patient is instructed not to restrict carbohydrate intake in the days or weeks before the test. The test should not be done during an illness, as results may not reflect the patient's glucose metabolism when healthy. A full adult dose should not be given to a person weighing less than 43 kg (94 lb), or exaggerated glucoses may produce a false positive result.

[edit] Procedure for OGTT

The patient should have been fasting for the previous 8-14 hours (water is allowed).

Usually the OGTT is scheduled to begin in the morning (0700-0800) as glucose tolerance exhibits a diurnal rhythm with a significant decrease in the afternoon. A zero time (baseline) blood sample is drawn.

The patient is then given a glucose solution to drink. The standard dose since the late 1970s has been 1.75 grams of glucose per kilogram of body weight, to a maximum dose of 75 g. It should be drunk within 5 minutes. Prior to 1975 a dose of 100 g was often used.

Blood is drawn at intervals for measurement of glucose (blood sugar), and sometimes insulin levels. The intervals and number of samples vary according to the purpose of the test. For simple diabetes screening, the most important sample is the 2 hour sample and the 0 and 2 hour samples may be the only ones collected. In research settings, samples may be taken on many different time schedules.

If renal glycosuria (sugar excreted in the urine despite normal levels in the blood) is suspected, urine samples may also be collected for testing along with the fasting and 2 hour blood tests.

[edit] Interpretation of OGTT results

Fasting plasma glucose should be below 6.1 mmol/l (110 mg/dl). Fasting levels between 6.1 and 7.0 mmol/l (110 and 126 mg/dl) are borderline ("impaired fasting glycaemia"), and fasting levels repeatedly at or above 7.0 mmol/l (126 mg/dl) are diagnostic of diabetes.

The 2 hour glucose level should be below 7.8 mmol/l (140 mg/dl). Levels between this and 11.1 mmol/l (200 mg/dl) indicate "impaired glucose tolerance." Glucose levels above 11.1 mmol/l (200 mg/dl) at 2 hours confirms a diagnosis of diabetes.


1999 WHO Diabetes criteria - Interpretation of Oral Glucose Tolerance Test
Glucose levels NORMAL impaired fasting glycaemia (IFG) impaired glucose tolerance (IGT) Diabetes Mellitus (DM)
Venous Plasma Fasting 2hrs Fasting 2hrs Fasting 2hrs Fasting 2hrs
(mmol/l) <6.1 <7.8 > 6.1 & <7.0 <7.8 <7.0 >7.8 >7.0 >11.1
(mg/dl) <100 <140 >100 & <125 <140 <125 >140 >126 >200

[edit] Variations

A standard 2 hour OGTT is sufficient to diagnose or exclude all forms of diabetes mellitus at all but the earliest stages of development. Longer tests have been used for a variety of other purposes, such as detecting reactive hypoglycemia or defining subsets of hypothalamic obesity. Insulin levels are sometimes measured to detect insulin resistance or deficiency.

The OGTT is of limited value in the diagnosis of reactive hypoglycemia, since (1) normal levels do not preclude the diagnosis, (2) abnormal levels do not prove that the patient's other symptoms are related to a demonstrated atypical OGTT, and (3) many people without symptoms of reactive hypoglycemia may have the late low glucoses that are said to be characteristic. Using a glucose tolerance in this context resembles use of a Rorschach test in that it is often used to support a diagnosis that the patient and doctor are already reaching agreement on based on other evidence, but it is inadequate by itself to confirm or refute the diagnosis (unlike its use for diabetes).

When the glucose is given intravenously it is termed an intravenous glucose tolerance test (IVGTT). This has been used in the investigation of early insulin secretion abnormalities in prediabetic states.

[edit] External links


Product Results:

Paper Label Permanent Adhesive This is for the "Glucose Tolerance Draw Time Label - 1000 Labels" model only. Categorization: Labels and Accessories > Preprinted Labels This product may differ from image shown (i.e. product may be a different color, size, make, model, or be a replacement part for product shown). If you have any questions or concerns, please contact us before placing your order.
Glucose tolerance Draw Time Label - 1000 Labels - Preprinted Glucose...
Lightweight, shatterproof glucose tolerance Plastic bottles won't shatter - never worry about breaking and leaking GTB! This is for the "Orange Glucose Tolerance - 50 Gram, 24/cs" model only. Categorization: Chemistry > Miscellaneous This product may differ from image shown (i.e. product may be a different color, size, make, model, or be a replacement part for product shown). If you have any questions or concerns, please contact us before placing your order.
Orange Glucose tolerance - 50 Gram, 24/cs - Glucose Tolerance -...
Lightweight, shatterproof glucose tolerance Plastic bottles won't shatter - never worry about breaking and leaking GTB! This is for the "Fruit Punch Glucose Tolerance - 75 Gram, 24/cs" model only. Categorization: Chemistry > Miscellaneous This product may differ from image shown (i.e. product may be a different color, size, make, model, or be a replacement part for product shown). If you have any questions or concerns, please contact us before placing your order.
Fruit Punch Glucose tolerance - 75 Gram, 24/cs - Glucose Tolerance -...
Lightweight, shatterproof glucose tolerance Plastic bottles won't shatter - never worry about breaking and leaking GTB! This is for the "Orange Glucose Tolerance - 100 Gram, 24/cs" model only. Categorization: Chemistry > Miscellaneous This product may differ from image shown (i.e. product may be a different color, size, make, model, or be a replacement part for product shown). If you have any questions or concerns, please contact us before placing your order.
Orange Glucose tolerance - 100 Gram, 24/cs - Glucose Tolerance -...
INDICATIONS: Blood Glucose Test Strips For blood glucose testing using products that feature the Prestige Smart System logo.
Blood Glucose test Strips For blood glucose testing - 50 ea

Search  for    ?
web dir image video media news gallery wiki shop 


↑ top of page ↑